CJDXH - RECHARGEABLE BATTERIES

  • MSDS: CJDXH
  • Manufacturer: POWER SONIC CORP
  • Product Name: RECHARGEABLE BATTERIES
  • National Stock Number: 6140-01-284-6351
Product Identification

Product ID:RECHARGEABLE BATTERIES
MSDS Date:01/02/1991
FSC:6140
NIIN:01-284-6351
MSDS Number: CJDXH

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 650-364-5001

Info Phone: 650-364-5001

Cage: 56309

Contractor
STANCIL CORP
SANTA ANA, CA 92704-5238 US

Telephone: 650-364-5001

Cage: 89178

Ingredients

CADMIUM & CADMIUM HYDROXIDE


NICKEL & NICKEL HYDROXIDE


POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE


COBALT HYDROXIDE

CAS: 21041-93-0

RTECS: GG0904500

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:EACH BATTERY CELL IS A SEALED
CYLINDRICAL CONTAINER. IF BROKEN, LEAKING OR IN FIRE: ACUTE -
POTASSIUM HYDROXIDE, SODIUM HYDROXIDE: BURNS TO TISSUE CONTACTED;
NICKEL: POSSIBLE CONTACT DERMATITIS. INGES TION CAUSES STOMACH
IRRITATION. CHRONIC- CADMIUM: POSSIBLE LUNG OR KIDNEY DAMAGE;
NICKEL: POSSIBLE LUNG DAMAGE.
Explanation of Carcinogenicity:CONTAINS CADMIUM AND NICKEL.
Effects of Overexposure:IF IN FIRE OR LEAKING: BURNS, IRRITATION, PAIN

First Aid

First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALED: REMOVE TO
FRESH AIR. CALL PHYSICIAN. EYES: FLUSH WITH WATER FOR 15 MINUTES.
HOLD EYELIDS OPEN. SEE PHYSICIAN. SKIN: WASH WITH LARGE AMOUNT OF
WATER; MILD ACID MAY BE USED TO NEUTRALIZE THE BASE. SWALLOWED: IF
BATTERY/OPEN BATTERY IS INGESTED, DO NOT INDUCE VOMITING OR GIVE
FOOD/DRINK. SEEK IMMEDIATE MEDICAL ATTENTION. CALL NATIONAL BATTERY
INGESTION H OTLINE FOR ADVICE & FOLLOWUP (202-625-3333).

Fire Fighting

Fire Fighting Procedures:IF INCINERATED NIOSH/MSHA APPROVED POSITIVE
PRESSURE SCBA.
Unusual Fire/Explosion Hazard:TOXIC CADMIUM OXIDE FUMES MAY BE RELEASED
DURING BURNING.

Accidental Release

Spill Release Procedures:FLUSH ELECTROLYTE SPILLS WITH WATER. DO NOT
BREAK OPEN BATTERY CELL.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE. DO NOT
SHORT CIRCUIT, MAY CAUSE BURNS.
Other Precautions:KEEP OUT OF REACH OF CHILDREN. DO NOT BREAK OPEN
BATTERY CELL.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SCBA (IF BURNED)
Ventilation:ADEQUATE
Protective Gloves:NEOPRENE OR PVC IF CELL BROKEN OPEN
Eye Protection:CHEMICAL GOGGLES IF CELL BROKEN OPEN
Other Protective Equipment:EYE BATH, WASHING FACILITY, LAB COAT OR
UNIFORM.
Work Hygienic Practices:GOOD PRACTICE REQUIRES THAT GROSS AMOUNT OF ANY
CHEMICAL BE REMOVED FROM THE SKIN AS SOON AS PRACTICAL.
Supplemental Safety and Health
PART NUMBER: 13-175; A19460-1. DO NOT BREAK OPEN BATTERY CELL. PROTECT
AGAINST CRACKING OF CASE MATERIAL. ADHERE TO PROPER CHARGING
PROCEDURE.

Chemical Properties

HCC:Z5
Appearance and Odor:EACH BATTERY CELL IS A SEALED CYLINDRICAL CONTAINER
ENCLOSING ELECTROLYTES.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:EXTREME HEAT, FIRE
Hazardous Decomposition Products:TOXIC FUMES

Disposal

Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL,
STATE, AND FEDERAL LAWS AND REGULATIONS. DO NOT INCINERATE OR
MUTILATE BATTERIES.

Transport

Transport Information:THESE BATTERIES ARE CONSIDERED "MANUFACTURED
ARTICLES" AS DEFINED IN 49 CFR 1910-1200 (C).

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.